Model 5400 Dual Sync Gen/Test Signal Generator

The Test Pat menu allows you to set the type of test pattern desired for the Primary
output. Refer to Appendix A of this data pack for a complete description of each test
pattern.

Use the controls to set the following:

Pattern Type – select the test signal type in the first window and the test signal
parameters in the second window. Refer to the 5400 Parameter Table given
earlier for a complete listing of the available test signals and their parameters.

You may choose to turn off the Y, Cr and/or Cb Channels of some video signals if desired
for test purposes (such as the need for a monochrome signal for example). To turn off one
or more channels, deselect the Enabled check box.

When the 5410 optional audio submodule is installed, you may embed an audio tone, pop,
beep or silent in the Primary serial output with the following controls:

Aud Select – selects the format of the audio test signal to be output on the AES
and analog audio outputs. Choices for the audio test signal include the following:

Silent – digital audio equivalent of a color black signal.

Tone – continuous 1 KHz tone.

Pop – continuous tone with one and two beat interrupts representing Channel 1
and Channel 2 respectively.

Beep – silent with one and two beat beeps representing Channel 1 and Channel 2
respectively.

Embed – select whether or not to embed the audio test signal selected above in the
Primary serial output.

5400-17