Making Reference Choices

Each generator can be independently set to operate either as a Master Sync Generator
(using an internal precision frequency reference), or genlocked to an external reference
source of either composite video or a 10 MHz sine or square wave. In addition, the
secondary generator can be set to lock to the primary generator in tracking mode. These
choices are made using the Pri and Sec Source controls in the Primary and Secondary
menus. Refer to the block diagram below.

When a generator is set to be genlocked (by selecting Config Ref in the Pri or Sec
Source
menu), a further selection must be made to configure the module to use either its
external genlock BNC (labeled Genlock/10 Mhz In on the module backplane) or the
Master Frame Reference which is distributed through the Avenue frame backplane. This
choice is made in the Config menu and provides the configured reference for both genera-
tors. The module will accept analog composite NTSC (525) or PAL (625), or a 10 MHz sine
or square wave as an external genlock signal.

In order to provide the ultimate in flexibility, the television line standard output for each
generator can then be set to either 525/60 Hz or 625/50 Hz. These output choices are
possible even when the generators are locked to a genlock input in a different standard.

5400-10

Master

Frame

Ref

Sync

Detector

Internal

Precision
Standard

Genlock/10 MHz

Primary Generator

Secondary Generator

Internal

Internal

Track
Primary

Config

Ref

Config

Ref

525/60 Hz

or

625/50 Hz

525/60 Hz

or

625/50 Hz

Pri Source

Master

Ext Video

Config Ref

Sec Source

Model 5400 Dual Sync Gen/Test Signal Generator

Primary and Secondary Reference Source Detail