beautypg.com

Appendixes – Ericsson LBI-39224 User Manual

Page 281

background image

LBI-39224

A-1

7. APPENDIXES

7.1 APPENDIX A - LOGGED ERROR DEFINITIONS

LOGGED

ERROR

MESSAGE

LOGGED

ERROR

DATA

CAUSE/

CORRECTIVE

ACTION

E00-xxx:
UNKNOWN ERROR

An error has been generated within
the CEC/IMC, but the CEC/IMC
Manager cannot determine what it
is. This is usually a result of a
Controller Board residing in the
system with firmware prior to
version 2.00 or with a firmware
version more recent than the
CEC/IMC Manager software
version. Corrective Action:
Ensure all Controller Boards in
system are equipped with firmware
version 2.00 or greater and the
CEC/IMC Manager contains a
software version greater than or
equal to the most recent Controller
Board firmware being used.

E01-019:
HW FAIL - AUDIO
BOARD

Data field is the
Board affected.

Audio board type does not match
configuration data, i.e. analog
board, but configured for digital.