Page 204

background image

LBI-39224

3-174

(

No

), or cancel the

Close

command (

Cancel

) and remain in the

DC Controlled Station State Table Mapping

dialog box.

3.15 LOGGING RECORDER CONFIGURATION

The Logging Recorder Interface Module (LRIM) interface is used to
record audio for selected units, groups and conventional channels. The
CEC/IMC supports four (4) LRIM devices, each device supporting up
to 64 modules and 32 channels. Each module assigns a unit, group, or
conventional channel to a specific LRIM channel.

Logging Recorder configuration is performed from the

Logging Recorder Configuration

dialog box. From the CEC/IMC

Manager menu bar select

Configure System

/

CEC/IMC Configuration

/

LRIM

to display the

Logging Recorder Configuration

dialog box, Figure 38.

Figure 38 Logging Recorder Configuration Dialog Box

Help

Choose the

Help

button to access the Help function. (Help is also

available by pressing the F1 key.)

The current Logging Recorder is displayed in the drop-down list box at
the top center of the

Logging Recorder Configuration

dialog box.

Select the desired Logging Recorder to view or configure from this list
box (LRIM 1 - 4).

The Module List list box contains all of the programmable
(configurable) modules for the selected Logging Recorder. The module
number, entity alias, channel number, and output level (volume) are