LBI-39224

6-3

4.

Connect the NETCLOCK/2 to an unused CEC/IMC Manager
COM port. See the cable wiring diagrams that follow.

The NETCLOCK/2 has two RS-232 serial ports. One is an output that
transmits the 26-character ASCII time/date data once each second in
Format 0 or Format 1. This is called the 1/sec interface or the
"REMOTE OUTPUT."

The other port responds to commands from the CEC/IMC Manager by
transmitting a 26-character ASCII time/date data in Format 0, Format 1,
or Format 2. This port transmits the data on the next even second after
receiving an ASCII "T" from the CEC/IMC Manager. This is the T-
CMD or "SERIAL COM" port. Refer to the section of the
NETCLOCK/2 instruction manual concerning NETCLOCK/2 data
formats for additional details.

6.2.1 Hardware Installation Notes

TIME DATA FORMAT

Select the required data format:

– FORMAT

0

No date setting.

– FORMAT

1

Date setting available.

– FORMAT

2

Only available when using the T-CMD

interface. Must use the Time Zone Correction setting
at the CEC/IMC Manager. No date setting capability.

T-CMD Interconnections

The T-CMD interface (RS-232) requires a 9-pin male connector at the
NETCLOCK/2. The CEC/IMC Manager end may be either 9-pin
female or 25-pin female, depending on the specific configuration of the
PC. (See Figure 59 below.)