Comms, Factory defaults – Allmand Brothers MB 6200 User Manual
Page 33
33
Type:
Sign Type
Action
BLANK
Sign is blanked at power up.
LAST
The last displayed sequence is displayed at power up. The sequence
shown is also the current display.
Empty
The sequence shown is the sequence that will be displayed at power
up.
ENTER appears on the start up screen only when there is an appropriate action
requiring its use.
Note
&
&
Comms
The communication parameters are displayed on this screen.
•
ADDR: SBC address is 65535. This is factory set and is not user configurable.
•
RATE: Communication rate is 19,200 BAUD. This is factory set and is not user configurable.
•
SIZE: Maximum size of communication packets is 1024 BYTES. This is factory set and is not user
configurable.
S B C
C O M M S
A D D R = _ _ _ _ _
R A T E = _ _ _ _ _
B A U D
S
I
Z E = _ _ _ _
B Y T E S
Keys:
Key
Action
B
Backup to previous screen or cancel SBC
address edits
Factory Defaults
This function will reset the SBC parameters to the factory default values. There is no menu for this
function.
Any SBC configuration data entered will be lost if Y is pressed. The sign
may not be usable until it is configured with appropriate controller software.
Caution
D O
Y O U
R E A L L Y
W A N T
T O
C H A N G E
T O
S B C
D E F A U L T S ?
Y = Y E S
N = N O
Keys:
Key
Action
Y
Y
ES TO ACCEPT THE
SBC
DEFAULT
N
No to cancel