0x1ff80), Proprietary: post – Airmar NMEA 2000® Depth, Датчики User Manual
Page 49

DST200 User Manual revision 1.000
Proprietary and Confidential
47
NMEA 2000® TRANSMITTED PARAMETER GROUP
PGN
130944
(0x1FF80)
Proprietary: POST
Single Frame:
No
Priority:
7/Y/N
Update Rate:
0/Y/N
Destination:
Global
Query Support:
Yes
Access Level:
0
Field
#
Name
Request
Param. DD
DF
Type Resolution
Value
Remark
1 Manufacturer Code
Yes
DD172 DF52 11 bits
1
135 (decimal)
Manufacturer Code for Airmar Technology.
2 Reserved bits
No
DD001 DF52 2 bits
1
0x3
All bits set to logic "1"
3 Industry Group
Yes
DD168 DF52 3 bits
1
4 (decimal)
Industry Group for "Marine Industry".
4 Control
Yes
N/A DF52 1 bit
1
0 = report previous values
1 = generate new values
Default value = 0
This field only applies when this PGN is
transmitted in response to a query. Periodic
transmissions of this PGN will always
generate new values.
5 Reserved bits
No
DD001 DF52 7 bits
1
0x7F
All bits set to logic "1"
6 Number of ID/test result pairs to follow
No
DD006 DF53 uint8
1 bit
0 to 252
This field contains 4 for this
product.
7 Test ID #1
No
DD005 DF53 uint8
1 bit
0 to 252
Refer to the Table of IDs and Failure Codes.
8 Test result #1
No
N/A DF53 uint8
1 bit
0x00 = Pass
0x01-0xEF = Fail
0xF0-0xFE = reserved
0xFF = Data Not Available
Refer to the Table of IDs and Failure Codes.
9 Variable number of fields, field 7 repeated
No
DD005 DF53 uint8
1 bit
0 to 252
Refer to the Table of IDs and Failure Codes.
10 Variable number of fields, field 8 repeated
No
N/A DF53 uint8
1 bit
0x00 = Pass
0x01-0xEF = Fail
0xF0-0xFE = reserved
0xFF = Data Not Available
Refer to the Table of IDs and Failure Codes.
Notes
This PGN is transmitted once automatically upon power up of the DST. Thereafter, it may be transmitted in response to a PGN 126208 Request Group Function message. Fields
1 and 3 must both be fully specified in the request in order for this PGN to be transmitted.
This PGN does not respond to ISO Requests (PGN 59904).