DST200 User Manual revision 1.000
Proprietary and Confidential
12
NMEA 2000® TRANSMITTED PARAMETER GROUP
PGN
065409
(0x0FF81)
Proprietary: Speed Pulse Count
Single Frame: Yes
Priority: 7/Y/Y
Update Rate: 0/Y/Y
Destination: Global
Query Support: Yes
Access Level: 0
Field
#
Name
Request
Param. DD
DF
Type Resolution
Value
Remark
1 Manufacturer Code
Yes
DD172 DF52 11 bits
1
135 (decimal)
Manufacturer Code for Airmar Technology.
2 Reserved bits
No
DD001 DF52 2 bits
1
0x3
All bits set to logic "1"
3 Industry Group
Yes
DD168 DF52 3 bits
1
4 (decimal)
Industry Group for "Marine Industry".
4 SID (Sequence ID)
No
DD056 DF53 uint8
1 bit
0 to 252
Unit-less number. Refer to section 2.2. for
an explanation of this field.
5 Duration of interval
No
N/A DF66 uint16
0.001 s 0 to 65.532 s
Duration of the most recent measurement
interval.
6 Number of pulses received
No
DD008 DF54 uint16
1
0 to 65532
Number of pulses received from the
paddlewheel sensor during the most recent
measurement interval.
7 Reserved bits
No
DD001 DF52 8 bits
1
0xFF
All bits set to logic "1"
Notes
DST200
DT200
No
DT200S
D200
No
D200ST
PGN 65409
supported in:
ST200
This PGN is transmitted in response to a PGN 126208 Request Group Function message. Fields 1 and 3 must both be fully specified in the request in order for this PGN to be
transmitted.
This PGN does not respond to ISO Requests (PGN 59904).
This PGN may be used along with an alternative speed sensor (e.g. GPS) to create a frequency versus speed profile for use in calibrating the paddlewheel speed sensor within the
device.
Field 5, duration of interval, will nominally be the same as the update rate, but reflects the actual duration, whereas the update rate setting reflects the desired duration.