0x1ef00), Proprietary: temperature filter – Airmar NMEA 2000® Depth, Датчики User Manual
Page 35

DST200 User Manual revision 1.000
Proprietary and Confidential
33
NMEA 2000® TRANSMITTED PARAMETER GROUP
PGN
126720-44
(0x1EF00)
Proprietary: Temperature Filter
Single Frame:
No
Priority:
7/Y/N
Update Rate:
0/N/N
Destination:
Address
Query Support:
Yes
Access Level:
1
Field
#
Name
Request
Param. DD
DF
Type Resolution
Value
Remark
1 Manufacturer Code
Yes
DD172 DF52 11 bits
1
135 (decimal)
Manufacturer Code for Airmar Technology.
2 Reserved bits
No
DD001 DF52 2 bits
1
0x3
All bits set to logic "1"
3 Industry Group
Yes
DD168 DF52 3 bits
1
4 (decimal)
Industry Group for "Marine Industry".
4 Proprietary ID (PID)
Yes
DD005 DF53 uint8
1 bit
44 (decimal)
44 = Temperature Filter
5 Filter type
Yes
N/A DF52 4 bits
1
0 = no filter
1 = basic IIR filter
2 through 14 = reserved
15 = data not available /
do not change
This field is stored in EEPROM and may be
changed with the Command Group Function
PGN 126208. The default value is 1 (basic IIR
filter).
The format and number of remaining fields in
this parameter group (starting with field 7)
depends on the contents of this field.
6 Reserved
No
DD001 DF52 4 bits
1
0xF
All bits set to logic “1”
7+ (Dependent upon filter type)
No
DD000 DF00 undef. undefined undefined
The use of the remaining bytes and the number of
CAN frames required varies according to the
filter type (field 5).
Notes
DST200
DT200
DT200S
D200
No
D200ST
PGN 126720-44
supported in:
ST200