Configuration information – Airmar NMEA 2000® Depth, Датчики User Manual
Page 43

DST200 User Manual revision 1.000
Proprietary and Confidential
41
NMEA 2000® TRANSMITTED PARAMETER GROUP
PGN
126998
(0x1F016)
Configuration Information
Single Frame:
No
Priority:
6/Y/N
Update Rate:
0/N/N
Destination:
Global
Query Support:
Yes
Access Level:
0
For further information about the NMEA 2000® protocol, including field descriptions refer to the document, NMEA 2000® Standard for Serial-Data
Networking of Marine Electronic Devices available from NMEA.
Notes
This PGN is transmitted in response to an ISO Request PGN 59904, or to a PGN 126208 Request Group Function message.
The contents of fields 1 and 2 are stored in nonvolatile memory, and may be programmed using the NMEA Command Group Function, PGN 126208.
To change the state of the Installation Description (fields 1 and 2), use the Command Group Function PGN 126208, specifying the individual fields in PGN 126998 as follows.
PGN 126998
Field Value
1
Desired variable length ASCII
string, up to 70 characters
2
Desired variable length ASCII
string, up to 70 characters