DST200 User Manual revision 1.000
Proprietary and Confidential
44
NMEA 2000® TRANSMITTED PARAMETER GROUP
PGN
128275
(0x1F513)
Distance Log
Single Frame:
No
Priority:
6/Y/Y
Update Rate:
1000 mS/Y/Y
Destination:
Global
Query Support:
Yes
Access Level:
0
For further information about the NMEA 2000® protocol, including field descriptions refer to the document, NMEA 2000® Standard for Serial-Data
Networking of Marine Electronic Devices available from NMEA.
Notes
DST200
DT200
No
DT200S
D200
No
D200ST
PGN 128275
supported in:
ST200
Special note for models DT200S and D200ST: On power-up, these units will automatically detect the presence or absence of an optional external speed/temperature sensor. If no
external sensor is detected, then PGNs 128259 and 128275 will not be provided. In this case, the Transmitted PGNs Group List PGN 126464 will exclude those PGNs from its list.
To change the Distance Since Last Reset, use the Command Group Function PGN 126208, specifying the individual fields in PGN 128275 as follows.
PGN 128275
Field Value
4
Desired value (usually 0 to reset log)
See also the following transmitted PGNs:
65409
Proprietary: Speed Pulse Count
126720-41
Proprietary: Calibrate Speed
126720-43
Proprietary: Speed Filter
128259
Speed