0x1ef00), Proprietary: calibrate temperature – Airmar NMEA 2000® Depth, Датчики User Manual
Page 28

DST200 User Manual revision 1.000
Proprietary and Confidential
26
NMEA 2000® TRANSMITTED PARAMETER GROUP
PGN
126720-42
(0x1EF00)
Proprietary: Calibrate Temperature
Single Frame: No
Priority: 7/Y/N
Update Rate: 0/N/N
Destination: Address
Query Support: Yes
Access Level: 1
Field
#
Name
Request
Param. DD
DF
Type Resolution
Value
Remark
1 Manufacturer Code
Yes
DD172 DF52 11 bits
1
135 (decimal)
Manufacturer Code for Airmar Technology.
2 Reserved bits
No
DD001 DF52 2 bits
1
0x3
All bits set to logic "1"
3 Industry Group
Yes
DD168 DF52 3 bits
1
4 (decimal)
Industry Group for "Marine Industry".
4 Proprietary ID (PID)
Yes
DD005 DF53 uint8
1 bit
42 (decimal)
42 = Calibrate Temperature
5 Temperature instance
Yes
2 bits
1
0=DeviceSensor,
1=Onboard Water Sensor,
2=Optional Water Sensor,
3=Data Not Available
Select sensor to be calibrated or reported on
6 Reserved
No
DD001 DF52
6
1
0x3F
All bits set to logic “1”
7 Temperature offset
No
N/A
N/A
int16
0.001 °K +/-32.764 °K
The actual range of
allowable values is -9.999
to +9.999 °K.
This field establishes a Temperature Offset
that is added to the measured raw temperature
value to produce the reported Water
Temperature.
This field is stored in EEPROM and may be
changed with the Command Group Function
PGN 126208. The default value is 0.000 °K.
Notes
DST200
DT200
DT200S
D200
No
D200ST
PGN 126720-42
supported in:
ST200
This PGN is transmitted in response to a PGN 126208 Request Group Function message. Fields 1, 3, and 4 must each be fully specified in the request in order for this PGN to be
transmitted.