Single line y-tube system considerations – AEC VacTrac Series Conveying Systems User Manual
Page 54

Single Line Y-Tube System Considerations
•
•
• 
• 
•
•
Single line Y piping systems use a common material line for all vacuum receivers 
connected to a pump and are typically used to convey material from a central supply to 
several stations. 
If you are installing a single line Y system, use Y tubes on the material lines. A Y tube 
is installed with the branch arm leading to the next station on top and the straight 
portion that supplies material to the station underneath. 
Connect a short-radius bend to the straight portion as close to the Y as possible.
You must connect a minimum 2-foot (61 cm) straight length of tube to this short radius 
bend on the horizontal before the material tubing drops to the receiving point. If 
possible, incline this tube approximately 
1
/
8
” per foot (1 cm per meter).
On single line Y systems, you must install check valves on material inlet tubes inside 
vacuum receivers. 
Note: Do not use SRH01 or SRC02 vacuum receivers on single line Y systems.
You can install a long- or short-radius bend on the last station, where a Y-tube is not 
needed. 
Figure 27: Recommended Single-Line Y-Tube Installation
Conveying System Mechanical Components Chapter 3: Installation