AEC VacTrac Series Conveying Systems User Manual
Page 102

Problem
Possible Cause
Possible Remedy
The alarm package is wired 
incorrectly. 
Correct wiring. Consult 
wiring diagram. 
Optional audible alarm is not 
functioning. 
 
(Refer to enclosed Control 
Panel Manual for specific 
instructions.)
Alarm package component 
failure. 
Troubleshoot and 
repair/replace problem. 
•
Blower is dead-headed.
Check for obstruction.
•
Vent valve is not
operating. Check for 
proper signal, voltage, and 
80 to 90 psi (552 to 621 
kPa) compressed air. 
•
Worn seals in blower.
Rebuild/replace blower.
•
Worn bearings in blower.
Rebuild or replace.
•
Loose drive belt(s).
Tighten or replace if worn.
Follow the vacuum path 
from the blower through the 
filter, piping, valves and 
material receivers to isolate 
where the loss occurs. 
Vacuum conveying rate is 
declining due to a vacuum 
loss in the system. 
Pump package blower 
problem. Use a cfm/cfh 
monitoring device to ensure 
that blower cfm/cfh is to the 
manufacturer’s 
specifications. 
Consult Service Engineer if 
problem persists. 
Filter chamber problem. The 
vacuum at the filter chamber 
should be the same as the 
blower generates. If the 
vacuum at the filter chamber 
is adequate, the problem is 
down line. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Conveying System Mechanical Components Chapter 6: Troubleshooting
101 of 136