AEC VacTrac Series Conveying Systems User Manual
Page 101

Problem
Possible Cause
Possible Remedy
Dump Delay time set to zero, 
or insufficient dump delay 
time. 
Set dump delay time to the 
time it takes the largest 
vacuum hopper in the system 
to dump. 
Dusty material. Optional 
cyclone separator or low-
head separator may be 
needed – Consult sales rep. 
Consult sales representative.
Filter chamber filter cartridge 
is becoming obstructed too 
frequently by fines and dust. 
Dusty material — Optional 
compressed air filter 
cleaning may be needed on 
filter chamber. 
Consult sales representative.
No material demand at 
receivers if none of the 
amber lights on the optional 
light board are lit. 
Normal operation. Pump 
packages shut off thirty (30) 
seconds after no demand is 
detected for the time 
programmed. 
Pumps and receivers are on-
line, but the pumps are not 
conveying material. 
 
(Refer to enclosed Control 
Panel Manual for specific 
instructions.) 
The on-line receivers are not 
assigned to the pumps that 
are on-line. 
Reconfigure the control 
panel, assigning the pumps 
to the desired hopper. 
Optional audible/visual alarm 
continues to signal after the 
Press-To-Silence button is 
pressed. 
 
(Refer to enclosed Control 
Panel Manual for specific 
instructions.) 
The alarm is triggered every 
time an alarm message 
displays. 
In cases where numerous 
alarm conditions occur, 
alarm messages build up in 
the display buffer. Each time 
one is released from the 
buffer, the alarm sounds. 
 
The operator may: 
 
 
•
Press the silence button
after
each
message
•
Disable the alarm using
 the control panel keypad 
 
•
Cancel No-Convey
 alarm(s) . 
 
Correct the problem causing 
the alarm. Alarm will not 
trigger again until another 
high vacuum condition 
occurs. If multiple alarm 
messages are in the buffer, 
the button may need to be 
pressed a few times. 
To cancel No Convey alarm(s):
• 
• 
• 
Take the problem receiver(s) off line with field-installed station bypass switches. 
Take the problem receiver(s) off line with the control panel. 
Remove the material demand by filling the bin below the vacuum receiver. 
Conveying System Mechanical Components Chapter 6: Troubleshooting
100 of 136