Figure 8: APD and APC Pump Specifications (Positive Displacement and Centrifugal pumps)

Model

Amp draw, full-load amps

Air flow

Line size

Ship weight

hp

230 V

460 V

575 V

cfm

inches

lbs.

Pumps — Positive Displacement Models

Vacuum Material

5 13.4

6.7

5.4 120 2.0”

2.0” 385

10 28.4

14.2

11.4 200 2.5”

2.5” 400

10 29.2

14.6

11.7 300 3.0”

3.0” 400

15 38.4

19.2

15.3 300 3.0”

3.0” 420

15 39.2

19.6

15.7 360 3.5”

3.5” 420

Pumps — Centrifugal Models

Vacuum Material

3.5 9.1

4.6 3.0 106 2.0”

1.5” 175

6.5 12.9 6.5 4.3 152 2.0”

2.0”

300

11

32.5

16.2

10.6

225

2.5”

2.5”

350

Model

Amp draw, full-load amps

Air flow

Line size

Ship weight

kW

230 V

460 V

575 V

cmh

mm

Kg

Pumps — Positive Displacement Models

3.75

13.4

6.7

5.4

204

50 mm

175

7.5 28.4

14.2

11.4 340

63

mm 181

11.25 38.4

19.2

15.3 510

76

mm 190

Pumps — Centrifugal Models

3.5 9.1

4.6

3.0

180

38

mm 80

6.5 12.9

6.5

4.3 258

50

mm 136

11

32.5

16.2

10.6

302

63 mm

159

Air flow measured in cubic feet per minute (cfm) and cubic meters per hour (cmh).

Rated performance is at standard atmosphere and sea level conditions. High
elevation affects system performance