Figure 8: APD and APC Pump Specifications (Positive Displacement and Centrifugal pumps)
Model
Amp draw, full-load amps
Air flow
Line size
Ship weight
hp
230 V
460 V
575 V
cfm
inches
lbs.
Pumps — Positive Displacement Models
Vacuum Material
5 13.4
6.7
5.4 120 2.0”
2.0” 385
10 28.4
14.2
11.4 200 2.5”
2.5” 400
10 29.2
14.6
11.7 300 3.0”
3.0” 400
15 38.4
19.2
15.3 300 3.0”
3.0” 420
15 39.2
19.6
15.7 360 3.5”
3.5” 420
Pumps — Centrifugal Models
Vacuum Material
3.5 9.1
4.6 3.0 106 2.0”
1.5” 175
6.5 12.9 6.5 4.3 152 2.0”
2.0”
300
11
32.5
16.2
10.6
225
2.5”
2.5”
350
Model
Amp draw, full-load amps
Air flow
Line size
Ship weight
kW
230 V
460 V
575 V
cmh
mm
Kg
Pumps — Positive Displacement Models
3.75
13.4
6.7
5.4
204
50 mm
175
7.5 28.4
14.2
11.4 340
63
mm 181
11.25 38.4
19.2
15.3 510
76
mm 190
Pumps — Centrifugal Models
3.5 9.1
4.6
3.0
180
38
mm 80
6.5 12.9
6.5
4.3 258
50
mm 136
11
32.5
16.2
10.6
302
63 mm
159
Air flow measured in cubic feet per minute (cfm) and cubic meters per hour (cmh).
Rated performance is at standard atmosphere and sea level conditions. High
elevation affects system performance
Conveying System Mechanical Components Chapter 2: Functional Description
27 of 136