Troubleshooting Checklist

4-6

Troubleshooting

Cannot contact
the 6H352-25
through in-band
management.

IP address not assigned.

Refer to the MATRIX E7 Series and
SmartSwitch 6000 Series Modules Local
Management User’s Guide
for the IP address
assignment procedure.

Port is disabled.

Enable port. Refer to the MATRIX E7 Series
and SmartSwitch 6000 Series Modules Local
Management User’s Guide
for instructions
to enable/disable ports.

No link to device.

1. Verify that all network connections

between the network management station
and the 6H352-25 are valid and operating.

2. If the problem continues, contact

Enterasys Networks for technical support.

Port(s) goes into
standby for no
apparent reason.

Loop condition detected.

1. Verify that Spanning Tree is enabled.

Refer to MATRIX E7 Series and
SmartSwitch 6000 Series Modules Local
Management User’s Guide
for the
instructions to set the type of STA.

2. Review the network design and delete

unnecessary loops.

3. If the problem continues, contact

Enterasys Networks for technical support.

User parameters
(IP address,
Device and
Module name,
etc.) were lost
when the
6H352-25 power
was cycled or the
front panel
RESET button
was pressed.

1. Position of Mode switch

(7), NVRAM Reset, was
changed sometime
before either cycling
power or pressing the
RESET button, causing
the user-entered
parameters to reset to
factory default settings.

2. Clear NVRAM was set

through Local
Management.

1. Reenter the lost parameters as necessary.

Refer to MATRIX E7 Series and
SmartSwitch 6000 Series Modules Local
Management User’s Guide
for the
instructions to configure the device
through Local Management.

2. If the problem continues, contact

Enterasys Networks for technical support.

Table 4-2

Troubleshooting Checklist (Continued)

Problem

Possible Cause

Recommended Action