Connecting to the Network

Installation

3-7

3.5

CONNECTING TO THE NETWORK

This section provides the procedures for connecting unshielded twisted pair (UTP) segments from
the network or other devices to the 6H352-25. Refer to the appropriate manual if connecting an
optional HSIM or VHSIM to the network. For details on how to get manuals, refer to the

Related

Documents

section in

About This Guide

.

The fixed front panel ports of the 6H352-25 are 10/100 RJ45 ports with internal crossovers. When
connecting a workstation to these ports, use a straight-through cable. When connecting networking
devices to these ports, such as a bridge, repeater, or router, use a crossover cable.

Connect a twisted pair segment to the 6H352-25 as follows:

1. Ensure that the device connected to the other end of the segment is powered ON.

2. Connect the twisted pair segment to the 6H352-25 by inserting the RJ45 connector on the

twisted pair segment into the desired RJ45 port as shown in

Figure 3-3

.

If the 6H352-25 is being installed in a network using SmartTrunking, there are rules
concerning the network cable and port configurations that must be followed for
SmartTrunking to operate properly. Before connecting the cables, refer to the

MATRIX

E7 Series and SmartSwitch 6000 Series Modules Local Management User’s Guide for
the configuration information.

All RJ45 front panel ports on the 6H352-25 support Category 5 Unshielded Twisted Pair
(UTP) cabling with an impedance between 85 and 111 ohms. Category 3 cable may be
used if the connection is going to be used only for 10 Mbps.