Lanview leds, Table 4-1 – Enterasys Networks Enterasys Matrix 6H352-25 User Manual
Page 39
Using LANVIEW
Troubleshooting
4-3
Table 4-1
LANVIEW LEDs
LED
Color
State
Recommended Action
CPU
Off
Power off.
Ensure chassis has adequate power.
Red
Blinking. Hardware
failure has occurred.
Contact Enterasys Networks for technical
support.
Solid. Resetting, normal
power up reset.
If the LED remains red for several minutes,
contact Enterasys Networks for technical
support.
Amber
Blinking. Crippled.
Contact Enterasys Networks for technical
support.
Solid. Testing.
If the LED remains amber for more than
several minutes, contact Enterasys
Networks for technical support.
Green
Solid. Functional.
None.
Amber
and
Green
Booting. Blinks amber
and green while booting.
None.
RX
(Receive)
Off
No link.
No activity or port in
standby. Port enabled or
disabled.
None.
Green
Solid. Link, port enabled,
no activity.
None.
Blinking. Link, port
disabled.
None.
Amber
Flashing. Link, port
enabled, activity.
None.
Red
Solid. Diagnostic failure.
Contact Enterasys Networks for assistance.