beautypg.com

Enterasys Networks Enterasys Matrix 6H352-25 User Manual

Page 40

background image

Using LANVIEW

4-4

Troubleshooting

TX
(Transmit)

Off

Port enabled, and no
activity.

Should flash green every
two seconds indicating
BPDUs being sent if STA
is enabled and there is a
valid link.

1. Ensure that the STA is enabled and that

there is a valid link.

2. Contact Enterasys Networks for technical

support.

Green

Flashing. Indicates
activity. Rate indicates
data rate.

None.

Amber

Blinking. Port in
standby.

Port may be disabled due
to Spanning Tree.

1. Ensure that the port is not disabled.
2. Contact Enterasys Networks for technical

support.

Red

Flashing. Indicates
collision rate.

None, unless there is a high amount of
activity. In this case, check for network
configuration problems or a defective
device.

Solid. Diagnostic failure.

Contact Enterasys Networks for technical
support.

Table 4-1

LANVIEW LEDs (Continued)

LED

Color

State

Recommended Action