Connecting to the Network

3-8

Installation

Figure 3-3

Connecting a Twisted Pair Segment to the 6H352-25

3.

Verify that a link exists by checking that the port RX (Receive) LED is ON (flashing amber,
blinking green, or solid green). If the RX LED is OFF and the TX (Transmit) LED is not
blinking amber, perform the following steps until it is on:

a.

To view the receive and transmit activity on a group of segments, press the GROUP
SELECT button (see

Figure 3-3

) to step to the group of interest (Group 1 or 2). Each time

the GROUP SELECT button is pressed, the GROUP LED lights up in sequence, indicating
which Group is selected. The receive and transmit activity for that group of segments is then
indicated by the RX and TX LEDs for each segment.

b. Verify that the cabling being used is Category 5 UTP with an impedance between 85 and

111 ohms. If the port is to operate at 100 Mbps, category 5 cabling must be used.

c.

Verify that the device at the other end of the twisted pair segment is on and properly
connected to the segment.

d. Verify that the RJ45 connectors on the twisted pair segment have the proper pinouts

(

Figure 3-4

and

Figure 3-5

) and check the cable for continuity. Typically, a crossover cable

is used between a switching or hub device and an end user (computer). A straight-through
cable is used between hub devices.

3547_04

FAST ENET

6H352-25

GROUP

GROUP

SELECT

RESET

COM

CPU

11X

1X

G

R

O

U

P

1

GROUP

Group Select Button

RX LED