SPECIFICATIONS

60

10.1.8 Shims specifications

When the product temperatures are above 60 °C always use one shim less than
indicated in the diagrams.

Always round up the number of shims.

6

7

0

0

120 140 160

100

80

60

40

20

5

4

3

2

1

25

DuCoNite

R

1600kPa - 16bar - 232psi

1250kPa - 12.5bar - 181psi

1000kPa - 10bar - 145psi

750kPa - 7.5bar - 109psi

500kPa - 5bar - 72.5psi

250kPa - 2.5bar - 36psi

0kPa - 0bar

5

4

3

2

1

0

0

20

40

60

80

100 120

140

32

DuCoNite

R

1600kPa - 16bar - 232psi

1250kPa - 12.5bar - 181psi

1000kPa - 10bar - 145psi

750kPa - 7.5bar - 109psi

500kPa - 5bar - 72.5psi

250kPa - 2.5bar - 36psi

0kPa - 0bar