beautypg.com

10 specifications, 1 pump head, 1 performance – Watson-Marlow DuCoNite 25 User Manual

Page 54

background image

SPECIFICATIONS

54

10

SPECIFICATIONS

10.1

Pump head

10.1.1 Performance

Description

DuCoNite

®

25

DuCoNite

®

32

Max. capacity, continuous [m

3

/h]

1.80

3.25

Max. capacity, intermittent [m

3

/h]

*

*

Intermittent duty: "Let the pump stand still to cool down for at least 1 hour after 2 hours of
operation".

2.88

5.25

Capacity per revolution [l/rev]

0.300

0.625

Max. permissible working pressure [kPa]

1600

Permissible ambient temperature [°C]

-20 to +45

Permissible product temperature [°C]

-10 to +60

Sound level at 1 m [dB(A)]

70