10 specifications, 1 pump head, 1 performance – Watson-Marlow DuCoNite 25 User Manual
Page 54

SPECIFICATIONS
54
10
SPECIFICATIONS
10.1
Pump head
10.1.1 Performance
Description
DuCoNite
®
25
DuCoNite
®
32
Max. capacity, continuous [m
3
/h]
1.80
3.25
Max. capacity, intermittent [m
3
/h]
*
*
Intermittent duty: "Let the pump stand still to cool down for at least 1 hour after 2 hours of
operation".
2.88
5.25
Capacity per revolution [l/rev]
0.300
0.625
Max. permissible working pressure [kPa]
1600
Permissible ambient temperature [°C]
-20 to +45
Permissible product temperature [°C]
-10 to +60
Sound level at 1 m [dB(A)]
70