MAINTENANCE

45

5.

Loosen the retaining bolt (A) of the pressing
shoe (B). Fit the shims (C) or remove them, until
the correct number of shims is present. Refer to
§

10.1.8

.

Fasten the retaining bolt of the pressing shoe
with the correct torque. Refer to §

10.1.7

.

6.

Refit the cover (B). Check the gasket (C) for
damage and replace if necessary. Make sure
that all bolts (A) are refitted and that they are
tightened in the correct order, diagonally
opposite each other. Refer to §

10.1.7

.

7.

Switch on the electrical supply.

8.

Jog the rotor until the second pressing shoe is
positioned between the inlet and outlet port.

9.

Isolate the pump from the electrical supply.

10.

Repeat the procedure for this pressing shoe by
repeating steps 4, 5, 6 and 7.

11.

Refill the lubricant via the breather. Refer to
§

7.5

.