MAINTENANCE

43

14.

Fit the removed shims (C) again. Position the
(new) pressing shoe (B), check that the Nord-
Lock

®

rings (D) have been positioned correctly

and tighten the retaining bolt(s) (A) a few turns.
Refer to §

10.1.7

.

15.

Check the gasket (C) for damage and replace if
necessary. Refit the cover (B). Make sure that
the 4 bolts (A) are refitted and that they are
tightened in the correct order, diagonally
opposite each other. Refer to §

10.1.7

.

16.

Switch on the electrical supply to the pump.

17.

Fit the (new) pump hose. Refer to §

7.7.3

.

7.9

Adjusting hose compression force
(shimming)

Remove the pump cover before fitting and removing
shims. In order to determine the correct number of
shims for your specific application refer to §

10.1.8

.

CAUTION
Too many shims, this means a too high
compression force on the pump hose, will
create a too high load on the pump head
and pump hose, which may result in a
reduction of the life of the pump hose and
bearings.