MAINTENANCE

29

Point

Action

To be carried out

Remark

1

Check the lubricant
level.

Before startup of the
pump and on a sched-
uled interval during oper-
ation.

Make sure that the lubri-
cant level is above the
minimum level line in the
inspection window.
If necessary refill the
lubricant. See also §

7.5

.

2

Check the pump head
for any leakage of lubri-
cant around the cover,
the flanges and the rear
of the pump head.

Before startup of the
pump and on a sched-
uled interval during oper-
ation.

See §

9

.

3

Check the gearbox for
any leakage.

Before startup of the
pump and on a sched-
uled interval during oper-
ation.

In case of leakage con-
sult your Bredel repre-
sentative.

4

Check the pump for
deviating temperature or
strange noises.

On a scheduled interval
during operation.

See §

9

.

5

Check the pressing
shoes for excessive
damage.

When replacing the
pump hose.

See §

7.7

.

6

Internal cleaning of the
pump hose.

Cleaning of the system
or product change.

See §

7.4

.

7

Replace the pump hose. Preventive, this means

after 75% of the hose life
of the first hose.

See §

7.7

.

8

Change lubricant.

After every 2

nd

hose

change or after 5,000
service hours, whichever
comes first or after hose
rupture.

See §

7.5

9

Change oil in the gear-
box.

Refer to the lubricant
table in §

10.2

.

See §

7.6

.

10

Replace the pump seal.

If necessary.

See §

7.8.2

.