beautypg.com

4 frequency controller – Watson-Marlow DuCoNite 25 User Manual

Page 23

background image

INSTALLATION

23

5.3.4

Frequency controller

If the hose pump is fitted with a Bredel Variable
Frequency Drive (VFD), consider the following points:

Take precautions so the motor does not re-start
automatically after an unscheduled stop.
In the event of a power or mechanical failure,
the Bredel VFD controls the motor to stop.
When the cause of the failure is removed, the
motor can restart automatically. The automatic
restart is dangerous to certain installations of
the pump.

Maximum permissible loads [N] on the

pump flange

Force

DuCoNite

®

25

DuCoNite

®

32

F1

600

600

F2

500

500

F3

200

200

CAUTION
In case of hose failure, the product or a
mixture of product and lubricant can leak
by the breather cap. If this risk is not
acceptable, drain piping can be connected,
refer to §

7.10.2

.

WARNING
The maximum pump temperature is 60 °C.
Above this temperature the corrosion
speed can rise excessively, depending on
the product.

WARNING
A Bredel VFD that is fitted without the con-
trol switch
starts automatically when power
is applied.

This manual is related to the following products: