Installation, Log-in, Installation -2 – Verilink IMUX (880-503137-001) Product Manual User Manual
Page 16: Log-in -2
Quick Set-Up
2-2
Verilink IMUX User Manual
Installation
Mount the shelf within an air-conditioned room on a standard 19”
or 23” rack. Refer to the Access System 3000: The Basics manual for
detailed module installation instructions and precautions.
CAUTION
Verilink components contain static-sensitive circuits. Before unpacking
the equipment, ensure you are wearing an anti-static wrist strap
connected to frame ground to prevent damage to circuits from
electrostatic discharge.
Install the IMUX module components as follows:
1. Install the rear connector interface module (DIM) into the back
of the MLS shelf, slots 5 and 8.
2. Install the IMUX modules into the corresponding front slots of
the MLS shelf.
3. Connect the data cables to the ports on the rear connector
interface modules.
The IMUX module verifies self-test (LEDs flash red, then green).
Log-In
Connect a Craft cable to the port labeled
LOCAL
on the front of the
SCM module.
Connect the other end of the Craft cable to your PC (or terminal).
Start a session in a terminal program.
1. Set your terminal parameters to:
•
19.2 kbit/s
•
8 data bits
•
No parity
•
One stop bit
•
No flow control
2. Press E
NTER
.
3. The prompt pSH+
>
>
>
> displays.
4. Type “craft” (use lowercase).
5. The prompt
Your Password displays.
6. Initially there is no password, press E
NTER
.
7. The SCM Main Menu displays.