beautypg.com

Triplett Fox 2 & Hound 3 – PN: 3399 User Manual

Page 39

background image

39

other clip of the FOX 2 to one wire and then the other, while

listening to the tracer tone on this clip with the HOUND 3. If

the level of the tracer tone drops significantly when the clip

is connected to one of the wires, this wire is probably OK

and the other wire is open. That is, the open wire is the one

that doesn’t drop the level of the tracer tone. If neither wire

drops the level of the tracer tone, they are probably both

open (or a good ground has not been used).

TRACER TONE

VISUAL CONT.

TALK

OFF / POLARITY

AUDIBLE CONT.

WARBLE

PULSE

CORDLESS

INTERFACE

UNLOCK

BATTERY TEST

AC / RING

REV NORM

STRONG

TONE

OPEN FAULT

WEAK TONE

Figure 7

Locating an Open

Leave the clip connected to the wire or wires that do not

“load down” the tracer tone. See Figure 7. Using the HOUND

3, follow the path of the wires by finding the strongest sig-

nal. An abrupt drop in the tracer tone level will occur at the

point of the open. Keep in mind, however, if tracing unseen

wires in the wall or ceiling, that the wires may pass behind a