6.1.9

Ohmmeter

6.1.9.1 Voltage Sense Mode

Range:

15 V DC auto-polarity or AC to 1 KHz
typical. NEG indicator is on for zero and
negative inputs.

Accuracy:

±20% -40 to 85 C.

Sensitivity:

1000 ohms per volt.

Overload:

Continuous: 50 VRMS.
Ten seconds: 120 VRMS.

6.1.9.2 Resistance Measurement Mode

Ranges:

R x 1 and R x 100.

Center Scale:

5 and 500 ohms.

Accuracy:

±2.0% of scale length ±0.5 ohms
0 to 50 C.
±3.0% of scale length ±0.5 ohms
-40 to 85 C.

Open Circuit
Voltage:

1.0 to 1.8 VDC. The VOM jack is
negative with respect to the COM jack.

Test Current:

R x 1 range: 400 mA max.
R x 100 range: 3.6 mA max.

Overload:

R x 1 range: fuse blows before damage.
R x 100 range: 35 VRMS continuous.