beautypg.com

0 specifications – Triplett 2000 User Manual

Page 34

background image

Page 34

6.0

SPECIFICATIONS

6.1

Electrical Specifications

6.1.1

DC Voltage

Ranges:

0.6, 3, 15, 60, and 300 VDC.

Accuracy:

±1.5% of full scale 0 to 50 C.
±2.5% of full scale -40 to 85 C.

Sensitivity:

1000 ohms per volt.

Overload:

Continuous: 20 VRMS or 5 times full
scale, whichever is greater, not to
exceed 600 VRMS.
Ten seconds: 30 VRMS or 10 times full
scale, whichever is greater, not to
exceed 700 VRMS.

6.1.2

DC milliAmps

Ranges:

15, 60, and 300 mADC.

Accuracy:

±1.5% of full scale 0 to 50 C.
±2.0% of full scale -40 to 85 C.

Burden Volts:

60 mV nominal at full scale. Leads and
fuse add 250 milliohms typical resistance.

Overload:

Fuse blows before damage.