Problem:

The Clamshell is slipping on the pipe or tube. (Fixed Pads)

Probable causes:

The clamping pads are not in full contact with the pipe or tube.

The clamping pressure is too light.

Scale and/or other foreign material is present on the pipe or tube.

Weld seams, swelling, or bumps under the clamping pads are preventing

full contact.

Dull Tool Bits are causing extra force in the axial and/or radial direction.

The pipe or tube wall is too thin which allows the tube wall to flex and the

machine to move.

Problem:

The tool bit will not reach the work

Probable causes:

Incorrect tool blocks are installed.

Incorrect tool bit is installed.

Problem:

The Clamshell will not center on the pipe or tube. (Fixed

Pads)

Probable causes:

Incorrect clamping pad set is installed.

Scale and/or foreign material is present on the pipe or tube.

One of the clamping Pads is on a seam.

The pipe or tube has an out-of-round condition or is oversized or

undersized.

Problem:

The Air Motor will not start.

Probable causes:

The air supply is shut off.

The air motor will not run free.

The Air motor needs lubrication.

Add lubrication and do not run the air motor for a few minutes. Then try

again.

Tap on the air motor casing lightly with a piece of wood or with a soft

rubber mallet.

The vanes may be sticking.

Sand or other foreign material is in the vanes of the air motor