beautypg.com

Tri Tool 601SBM Clamshell Air User Manual

Page 37

background image

37

Model 601SBM Low Profile Clamshell

92-0092 Rev. 131230

The Main Bearing pre-load is too loose.

Problem:

The surface finish is rough

Probable causes:

The tool bit is dull, chipped, etc.

Metal build-up on the cutting edge of the tool bit is creating a false cutting

edge.

Cutting fluid is required.

The cutting speed is incorrect.

Problem:

The Headstock is hard to rotate by hand

Probable causes:

The Air Motor is still engaged.

The Clamping Pads are too tight on the pipe or tube.

Foreign material is on the mating surface of the split-lines.

Chips and/or other foreign material are in the rotating section.

The Tool Bit is in contact with the pipe or tube.

The Tool Block is in contact with the pipe or tube.

Problem:

The tool holder is not feeding

Probable causes:

The feed pin is broken or out of position.

The feed sprocket shear pin is broken.

The feed screw is stripped.

The feed nut is stripped.

The slide rails are too tight.

Problem:

There is a loss of air power

Probable causes:

The air supply pressure is too low.

The air filter is plugged.

The air line size is insufficient.

The air line is too long.

The motor is icing up because the water trap in the FRL has not been

drained.