Tri Tool 600RBL and 600SB Series OD Tracking Module User Manual
Page 20

20
TRI TOOL INC.
92-0732 Rev. 131009
Problem: The Headstock is hard to rotate by hand
The hydraulic motors are engaged.
The clamping pads are too tight on the pipe or tube.
Foreign material is on the mating surface of the split lines.
Chips and/or other foreign material are in the rotating section.
The Tool Bit is in contact with the pipe or tube.
The tool block is in contact with the pipe or tube.
The main bearing pre-load is too tight.
Problem: The Tool Holder is not feeding
The feed pin is broken or out of position.
The feed sprocket shear pin is broken.
The feed screw is stripped.
The feed nut is stripped.
The slide rails are too tight.
Problem: There is a loss of air power
The air supply pressure is too low.
The air filter is plugged.
The air line size is insufficient.
The air line is too long.
Problem: There is a loss of hydraulic power
The hydraulic supply pressure is too low.
The hydraulic filter is plugged.
The hydraulic line size is insufficient.
The hydraulic line is too long.
Problem: The Tool Bit will not reach the work
Incorrect tool blocks are installed for the size of the pipe or tube.
Incorrect Tool Bit is installed.