beautypg.com

Maintenance – Tri Tool 212B Beveler Single Point Flange Facer User Manual

Page 21

background image

21

92-0729 : Rev. 070928

212B BEVELMASTER

TM

SINGLE POINT / FLANGE FACER

MAINTENANCE

GENERAL:

All components should be cleaned and coated with a light film of oil prior to
use. Use a clean, non-detergent oil, preferably SAE 10 (90 SSU) or lighter.
If the 212B Series Single Point is operated in such a manner that the tool
holder collect debris while cutting, the tool holder and the feed shaft should
be cleaned after each cutting operation.
Tool life may be severely shortened, unless chips and/or other debris that
have been deposited on the cutting head during the machining operation are
removed.

RECOMMENDED MAINTENANCE SCHEDULE:

Daily maintenance when the unit is in operation includes wiping the unit down
and spraying with rust preventative under severe humidity conditions.
Visually inspect for loose screws, missing screws, damage, etc.
After every 20 hours of actual operation, lubricate the male and female tool
holder slides.
After every 40 hours of actual operation, thoroughly clean and lubricate male
and female tool slides, and tripper bracket assembly.
If the 212B Series Single Point is to be stored or if it will remain out of service
for a significant period of time (30 days or more), it should be thoroughly
cleaned, lubricated and sprayed with a rust preventative prior to storage.

TOOL HOLDER MAINTENANCE:

Clean the tool holder, and the feed components.
Inspect these parts for damage and replace as required.
Lubricate and reassemble.

LUBRICANT RECOMMENDATIONS:

The slide rails and tool holder require a light oil such as SAE 10 light
machine oil.
The tripper bracket assembly also require a SAE 10 light machine oil for
normal conditions and under dusty conditions a silicone, graphite or
molybdenum disulfide ‘dry’ lubricant.
A light film of all purpose grease may be used, but it must be checked for grit
contamination frequently.

This manual is related to the following products: