Depending upon the application,

each channel can be switched in-

dividually even in high-impedance

mode (HZ) in order to drive 70

Vrms or 100 Vrms loudspeaker

lines directly without an output

transformer (Direct Drive).

The power output by the DSA

multi-channel power amplifiers is

(along with its thermal capacity)

limited only by their maximum

output voltage and maximum

output current, which means they

can drive any load between 2 and

10 ohms with their rated maximum

outputs of 500 W and 1000 W res-

pectively per channel.

a corresponding encoder-circuit

is provided on the rear panel. in

addition, through vld (variable

load drive) in combination with

a rcM-810 remote control module,

it is possible to define freely

which output power should be

made available at which load in

the frame described above in the

channel in question: e.g. channel

A = 350 W into 2.6 Ω; Channel B =

500 W into 8 Ω; Channel C = 200 W /

100v etc.

The fact that an output trans-

former has been dispensed with

the highly efficient Class-D power

amplifiers and switching power

supply yields an extremely attractive,

environment- and resource sparing

amplifier. For applications involving

mandatory galvanic separation of

the connected loudspeakers in

accordance with EN 60849 and

IEC 60364 separate transformer

modules are available, optionally.

Input level controls on the rear

panel as well as LED meters and

control indicators on the front

panel offer a high degree of user

comfort. It goes without saying

that all protective circuits and dy-

namic limiters (as is the case with

in all DYNACORD power amplifiers)

are available in every channel. Using

the ON DELAY selector switch

on the rear panel of the power

amplifier, you can set the interval

of time by which the switching

on process should be delayed. In

Standby mode, the power consump-

tion of the device is reduced to a

minimum. Standby mode can be

activated via IRIS-Net or the POWER

REMOTE socket.

The Phoenix inputs marked IN-

PUT are electronically balanced.

Phoenix connectors are also provi-

ded for the power outputs.

The POWER REMOTE connector

makes the task of remote controlling

the power amplifier as well as

switching it on and off simple. For

further remote-supervision and

–control possibilities and integration

into IRIS-Net networks, an optional

remote control module (RCM-810)

is available.