Alarms – Thinklogical TLX Matrix Switch SNMP Traps User Manual
Page 7

®
TLX Matrix Switch SNMP Traps Manual
3
Rev. E - July, 2015
ALARMS
High Temperature Alarm
Begin and Clear
An SFP module has the ability to monitor and trigger an alarm on a high or low temperature reading. This
ability is internal to the SFP and is part of the digital diagnostic interface common to many SFPs. This
notification is sent when bit 7 of byte 112 in the real-time diagnostic registers changes from 0 to 1 (Begin) or
from a 1 to a 0 (Clear).
This bit is set when the internal temperature of the SFP exceeds the high temperature alarm level. The SFP
temperature is stored at bytes 96 and 97 of the SFP diagnostic register table.
Begin OID:
1,3,6,1,4,1,17658,2,2,2,0,1
Clear OID:
1,3,6,1,4,1,17658,2,2,2,0,2
Objects:
1: sfpLabel
2: sfpTemperature
3: sfpThresholdHighTempAlarm
4: sysContact
5: sysDescr
6: sysLocation
7: sysName
Low Temperature Alarm
Begin and Clear
An SFP module has the ability to monitor and trigger an alarm on a high or low temperature reading. This
ability is internal to the SFP and is part of the digital diagnostic interface common to many SFPs. This
notification is sent when bit 6 of byte 112 in the real-time diagnostic registers changes from 0 to 1 (Begin) or
from a 1 to a 0 (Clear).
This bit is set when the internal temperature of the SFP exceeds the high temperature alarm level. The SFP
temperature is stored at bytes 96 and 97 of the SFP diagnostic register table.
Begin OID:
1,3,6,1,4,1,17658,2,2,2,0,3
Clear OID:
1,3,6,1,4,1,17658,2,2,2,0,4
Objects:
1: sfpLabel
2: sfpTemperature
3: sfpThresholdLowTempAlarm
4: sysContact
5: sysDescr
6: sysLocation
7: sysName
High Vcc Alarm
Begin and Clear
An SFP module has the ability to monitor and trigger an alarm on a high or low Vcc voltage reading. This
ability is internal to the SFP and is part of the digital diagnostic interface common to many SFPs. This
notification is sent when bit 5 of byte 112 in the real-time diagnostic registers changes from 0 to 1 (Begin) or
from a 1 to a 0 (Clear).
This bit is set when the internal temperature of the SFP exceeds the high temperature alarm level. The SFP
temperature is stored at bytes 98 and 99 of the SFP diagnostic register table.
Begin OID:
1,3,6,1,4,1,17658,2,2,2,0,5
Clear OID:
1,3,6,1,4,1,17658,2,2,2,0,6
Objects:
1: sfpLabel
2: sfpTemperature
3: sfpThresholdHighVccAlarm
4: sysContact
5: sysDescr
6: sysLocation
7: sysName