Tlx640 hardware alarms (alarm contacts) – Thinklogical TLX Matrix Switch SNMP Traps User Manual
Page 19
![background image](https://www.manualsdir.com/files/807773/content/doc019.png)
®
TLX Matrix Switch SNMP Traps Manual
15
Rev. E - July, 2015
TLX640 HARDWARE ALARMS (Alarm Contacts)
Power Supply 1 Failure
Begin and Clear
Contact 1
TLX640 Power Supply 1 has failed (Begin) or is restored (Clear).
Begin OID:
1,3,6,1,4,1,17658,3,14,0,1
Clear OID:
1,3,6,1,4,1,17658,3,14,0,2
Objects:
1: tlxSwitchPSlabel
2: tlxSwitchPSstatus
3: sysContact
4: sysDescr
5: sysLocation
6: sysName
Power Supply 2 Failure
Begin and Clear
Contact 2
TLX640 Power Supply 2 has failed (Begin) or is restored (Clear).
Begin OID:
1,3,6,1,4,1,17658,3,14,0,3
Clear OID:
1,3,6,1,4,1,17658,3,14,0,4
Objects:
1: tlxSwitchPSlabel
2: tlxSwitchPSstatus
3: sysContact
4: sysDescr
5: sysLocation
6: sysName
Power Supply 3 Failure
Begin and Clear
Contact 3
TLX640 Power Supply 3 has failed (Begin) or is restored (Clear).
Begin OID:
1,3,6,1,4,1,17658,3,14,0,15
Clear OID:
1,3,6,1,4,1,17658,3,14,0,16
Objects:
1: tlxSwitchPSlabel
2: tlxSwitchPSstatus
3: sysContact
4: sysDescr
5: sysLocation
6: sysName
Power Supply 4 Failure
Begin and Clear
Contact 4
TLX640 Power Supply 4 has failed (Begin) or is restored (Clear).
Begin OID:
1,3,6,1,4,1,17658,3,14,0,17
Clear OID:
1,3,6,1,4,1,17658,3,14,0,18
Objects:
1: tlxSwitchPSlabel
2: tlxSwitchPSstatus
3: sysContact
4: sysDescr
5: sysLocation
6: sysName