Tlx320 hardware alarms (alarm contacts) – Thinklogical TLX Matrix Switch SNMP Traps User Manual
Page 17

®
TLX Matrix Switch SNMP Traps Manual
13
Rev. E - July, 2015
TLX320 HARDWARE ALARMS (Alarm Contacts)
Power Supply 1 Failure
Begin and Clear
Contact 1
TLX320 Power Supply 1 has failed (Begin) or is restored (Clear).
Begin OID:
1,3,6,1,4,1,17658,3,14,0,1
Clear OID:
1,3,6,1,4,1,17658,3,14,0,2
Objects:
1: tlxSwitchPSlabel
2: tlxSwitchPSstatus
3: sysContact
4: sysDescr
5: sysLocation
6: sysName
Power Supply 2 Failure
Begin and Clear
Contact 2
TLX320 Power Supply 2 has failed (Begin) or is restored (Clear).
Begin OID:
1,3,6,1,4,1,17658,3,14,0,3
Clear OID:
1,3,6,1,4,1,17658,3,14,0,4
Objects:
1: tlxSwitchPSlabel
2: tlxSwitchPSstatus
3: sysContact
4: sysDescr
5: sysLocation
6: sysName
Low Fan Speed
Begin and Clear
Contact 3
A fan in the Fan Tray has failed (Begin) or is restored (Clear).
Begin OID:
1,3,6,1,4,1,17658,3,14,0,5
Clear OID:
1,3,6,1,4,1,17658,3,14,0,6
Objects:
1: sysContact
2: sysDescr
3: sysLocation
4: sysName
Temperature Warning
Begin and Clear
Contact 4
The system has detected a temperature that is above the preset warning threshold (Begin) or is now below
the preset alarm threshold (Clear).
Begin OID:
1,3,6,1,4,1,17658,3,14,0,7
Clear OID:
1,3,6,1,4,1,17658,3,14,0,8
Objects:
1: sysContact
2: sysDescr
3: sysLocation
4: sysName