INSTALLATION GUIDELINES SERIES HEATING CABLES

PAGE 3

THERMON...The Heat Tracing Specialists

®

TEP0118U-1111

Upon receipt of Thermon heat tracing materials

Check the supplied materials and quantities against the
packing list. In case of deviations please contact Thermon
within 3 working days.

A) Inspection of the series heating cable

1. Check the printing or label on the heating cable to

make sure that the correct type has been received (if
applicable).

2. Check the printing on the cold lead cable to make sure

that the cable with the correct conductor size has been
received (if applicable).

3. Inspect visually for any damage incurred during

shipment.

4. Store in a dry place.
5. Cables should be handled with care to avoid crushing,

twisting or kinking.

Caution:
Do not connect power to the heating cable while it is on the
reel or in the shipping carton.

B1) Inspection of accessories for heat tracing cable using

IND and EX expediter or wall mounted JB-K type.

Cable relevant accessories
Whenever cable entry, power termination or end
termination is involved, Thermon series cable accessories
are related to the cable dimensions.

M20-PT100/TES-Exe : Gland for TES cables.
M25-TES2-Exe : Gland for TES cables.

MI cold lead cable is supplied with brass M20 or M25
glands.

General accessories
- circuit switches
- thermostats (TED1-..., T1-/T2-..., TC1-...,TS-...)
- junction boxes (JB-K...)
- SS mounting bracket (XP-1...) for junction boxes/

thermostats

- fixing tape (FT-1L/FT-1H)
- aluminium tape (AL-20H/AL-30H)
- SS clamps (ABA-25/ABA-40)/ SS B-type banding (B-4/
B-10/B-21)
- SS punch strip
- SS banding + seals
- Tool type LN
- Caution Labels (CL-E-...)
- Insulation Entry Kit (IEK-TES)
- Power and End Termination Kits (PETK-5, -6 and -7)

- Connector set (CETI 1525, TESFIT and CKTES-1 and -2)
- Cable protectors

B2) Inspection of accessories for heat tracing cable using

expediter or wall mounted Terminator type.

Cable relevant accessories
Whenever cable entry, power termination or end
termination is involved, Thermon series cable accessories
are related to the cable dimensions.

M20-PT100/TES-Exe : Gland for TES cables.
M25-TES-Exe : Gland for TES cables.

Z . - R-XP/WP type: TES
Z . - MI-WP type: MI

MI cold lead cable is supplied with brass M20 or M25
glands.

General accessories

- circuit switches
- thermostats (ZT-...)
- junction boxes (ZP-...)
- SS mounting bracket (XP-1-....) for junction boxes/

thermostats

- fixing tape (FT-1L/FT-1H)
- aluminium tape (AL-20H/AL-30H)
- SS clamps (ABA-25/ABA-40)/ SS B-type banding (B-4/
B-10/B-21)
- SS punch strip
- SS banding + seals
- Tool type LN
- Caution Labels (CL-E-...)
- Insulation Entry Kit (IEK-TES)
- Power and End Termination Kits (PETK-5, -6 and -7)
- Connector set (CETI 1525, TESFIT and CKTES-1 and -2)
- Cable protectors

This manual is related to the following products: