INSTALLATION GUIDELINES SERIES HEATING CABLES

PAGE 13

THERMON...The Heat Tracing Specialists

®

TEP0118U-1111

heating cable

Installation on pumps

NPS

½"

12

600

¾"

20

900

1"

25

1200

40

1200

2"

50

1500

2½"

65

1800

3"

80

2100

4"

100

3000

6"

150

4800

8"

200

6600

10"

250

8400

12"

300

10000

14"

350

11800

16"

400

13800

18"

450

16200

20"

500

18000

TYPICAL CABLE ALLOWANCES

PER PUMP

(single pass) in mm

N
O

M

I

N

A

L

P

I

P

E

S

I

Z
E

P
U

M

P

DN

FT fixing tape /
SS tie wire

Note:
- The heating cables should not touch or cross one

another.

- When prescribed in design apply aluminium tape over

the heating cable.

- Min. bending radius of the heating cable is 5-6 x cable

diameter.

- Apply additional SS tie wire/fixing tape in such a way

that heating cable makes close contact with the pump.