INSTALLATION GUIDELINES SERIES HEATING CABLES

PAGE 12

THERMON...The Heat Tracing Specialists

®

TEP0118U-1111

Installation on valves

FT fixing tape /
SS tie wire

heating cable

NPS

½"

12

150

300

--

¾"

20

220

450

--

1"

25

300

600

300

1½"

40

450

600

450

2"

50

600

750

600

2½"

65

900

750

3"

80

1050

750

4"

100

1500

900

6"

150

2400

1050

8"

200

3300

1200

10"

250

4200

1350

12"

300

5000

1500

14"

350

5900

1650

16"

400

6900

1800

18"

450

8100

1950

20"

500

9000

2100

TYPICAL CABLE ALLOWANCES

PER VALVE *

(single pass) in mm

B
U

T
T
E

R

F
L

Y

N
O

M

I

N

A

L

P

I

P

E

S

I

Z
E

S

C
R

E

W

E

D

F
L

A

N
G

E

D

DN

Note:
- The heating cables should not touch or cross one

another.

- When prescribed in design apply aluminium tape over

the heating cable.

- Min. bending radius of the heating cable is 5-6 x cable

diameter.

- Apply additional SS tie wire/fixing tape in such a way

that heating cable makes close contact with the valve.

* Allowances for valves up to

600 Lbs and a single pass of
heating cable