2.11 Cobranet Mixer

2.11.1 Cobrane Rreceiver Setting

Figure 42

-

Bundle No.: receive the Bundle number from the sending end. For the value range and setting method, see the

sending setting.

-

Priority level: the receiving priority compared with other bundle numbers. The larger the value is, the higher the

priority level is. If the levels are the same, the principle of first-come, first-served shall be followed. It is only effective when
the network processing capability is insufficient. The value range is between 0 and 255.

-

Activation state: the green lamp is on with sending end, and the gray lamp is on without sending end.

-

Sub-channel: the corresponding channel under the bundle number. Each bundle number is allowed to carry 8-way

audio data at most at the same time. The value range is 0 and 33-64. 0 indicates not use, and 33-64 correspond to the
analog output 1-32 respectively, which can be modified according to the specific circumstances.






2.11.2 Cobranet Ooutput