Page 24: 4 – recording

background image

24

TASCAM DA-3000

4 – Recording

Monitoring the input signal

Input signal monitoring is usually only on during recording and

when in recording standby. You can, however, also enable input

monitoring when the unit is stopped.
When Input signal monitoring is turned ON, playback is not

possible but Recording can be performed. In order to listen to

previously recorded audio, please turn the Input monitor OFF.
Follow the procedures below to make this setting.
1. Press the MENU button repeatedly to open the

I/O

SETTINGS

menu, and turn the MULTI JOG dial to select

IN

MONITOR

.

2. Press the MULTI JOG dial to open the

INPUT MONITOR

screen.

3. Turn the MULTI JOG dial to turn input monitoring on or off.

Options: OFF (default), ON

4. Press the MULTI JOG dial to confirm the selection and return

to the menu screen.

NOTE

Monitoring cannot be turned on during playback or when

paused.

Adjusting the input signal level

You can use the menu to adjust the level of the input signal.
1. Press the MENU button repeatedly to open the

I/O

SETTINGS

menu, and turn the MULTI JOG dial to select

INPUT VOL.

.

2. Press the MULTI JOG dial to open the

INPUT VOLUME

screen.

NOTE

The

LEVEL

item shows the input levels.

3. Turn the MULTI JOG dial to adjust the

VOLUME

item, which

is the input signal level.

Options: MUTE, −60dB – +12dB (default: 0.0dB)

CAUTION

The level meter OVER indicators will light at the following

levels. If the DSD mode is set to +3, though, they will light at

+3dB and higher.

• PCM recording and playback: 16-bit full-scale

• DSD recording and playback: 0dB

4. Press the MULTI JOG dial to confirm the selection and return

to the menu screen.

NOTE

The input signal level setting is retained even when the unit

is off.

Setting the peak hold indicators

You can set how long the peak hold indicators appear on the

level meters.
1. Press the MENU button repeatedly to open the

UTILITY

menu, and turn the MULTI JOG dial to select

PEAK HOLD

.

2. Press the MULTI JOG dial to open the

PEAK HOLD

screen.

3. Turn the MULTI JOG dial to set how long the peak hold

indicators appear.

Options:

“OFF”: No Peak Hold indicators are shown.

“1s” - “10s” : The peak hold indicator will remain shown

for the selected number of seconds.

(default: “2s”)

“INF.”: Peak Hold indicators are shown until the EXIT/

CANCEL [PEAK CLEAR] button is pushed.

4. Press the MULTI JOG dial to confirm the selection and return

to the menu screen.