The printed circuit board underneath the JP7 terminal block can reach a normal operating temperature of

approximately 90 °C. The controller specifications are based on using wires connecting to JP7 to meet UL 1015

requirements and have a wire size of 2.02 mm

2

effective cross-sectional area, which is comprised of 41 strands of

0.254 mm diameter copper wire. The effective equivalent wire size is 14 AWG. The specifications are further based

on a wire length of 410 mm between the power supply and the controller and a wire length of 920 mm between the

controller and the TE device. Using wire with a smaller conductor cross section and/or shorter in length might cause

abnormally high temperature to be present on the JP7 terminal block and wire. If smaller and/or shorter wire must

be used, the amount of current the controller can safely accept might need to be decreased and/or the ambient

temperature at which the controller can operate might need to be lowered.

The wires inserted into connector JP7 should have a strip length of 7 mm, be fully inserted into the connector, and

the JP7 screw terminals should be tightened with a minimum torque of 0.5 N-m. The allowable cross sectional area

for the conductors is 0.2 — 2.5 mm2 (AWG 24 — 14).

The wires inserted into connector JP2 should have a strip length of 9-10 mm and be fully inserted into the connector.

Do not allow uninsulated wire strands to create electrical shorts between adjacent terminals. The allowable cross

sectional area for the conductors is 0.2 — 1.5 mm

2

(AWG 24 — 16), except 0.16 mm

2

(26 AWG) wire can be used for

the sensor inputs.