Studio Technologies 76DA V.4.12 User Manual
Page 26

Issue 9, May 2014
Model 76DA/77 User Guide
Page 26
Studio Technologies, Inc.
for Surround
 
 Address 
Dim LED
Reference Level LED
A1
OFF
OFF
A2
OFF
ON
A3
ON
OFF
A4
ON
ON
Figure 9. Model 71 Device Address Chart
Figure 8. Model 71 Control Console Front and 
Back Panels
Device Address
The dim and reference level LEDs will 
display the Model 71’s current device 
address. The rotary level control is used 
to select the desired device address; the 
LEDs will respond accordingly. The device 
address must be selected so as not to con-
flict with the device address of any other 
connected Model 71 or Model 77 Control 
Console. The choices are A1, A2, A3, 
and A4. All Model 71 units have a default 
device address of A4; Model 77’s units 
have a default device address of A1. This 
ensures that, in most cases, no change 
will have to be made. Refer to Figure 9 for 
details.
Button Disable
To disable the Model 71’s buttons, simulta-
neously press and hold both the dim and 
reference buttons for two seconds. When 
the disable request has been recognized 
the LEDs above both buttons will flash 
rapidly. Release the buttons and they will 
no longer enable or disable their normal 
functions. To return the buttons to normal 
operation simultaneously press and hold 
both buttons for two seconds at which time 
the two LEDs will flash rapidly.
To leave the configuration mode and return 
a Model 71 to normal operation requires 
one last action: again press and hold its 
configuration button for two seconds. The 
selected configuration parameters will be 
stored in a nonvolatile memory device that 
is located inside this specific Model 71.