Studio Technologies 76DA V.4.12 User Manual
Page 26
Issue 9, May 2014
Model 76DA/77 User Guide
Page 26
Studio Technologies, Inc.
for Surround
Address
Dim LED
Reference Level LED
A1
OFF
OFF
A2
OFF
ON
A3
ON
OFF
A4
ON
ON
Figure 9. Model 71 Device Address Chart
Figure 8. Model 71 Control Console Front and
Back Panels
Device Address
The dim and reference level LEDs will
display the Model 71’s current device
address. The rotary level control is used
to select the desired device address; the
LEDs will respond accordingly. The device
address must be selected so as not to con-
flict with the device address of any other
connected Model 71 or Model 77 Control
Console. The choices are A1, A2, A3,
and A4. All Model 71 units have a default
device address of A4; Model 77’s units
have a default device address of A1. This
ensures that, in most cases, no change
will have to be made. Refer to Figure 9 for
details.
Button Disable
To disable the Model 71’s buttons, simulta-
neously press and hold both the dim and
reference buttons for two seconds. When
the disable request has been recognized
the LEDs above both buttons will flash
rapidly. Release the buttons and they will
no longer enable or disable their normal
functions. To return the buttons to normal
operation simultaneously press and hold
both buttons for two seconds at which time
the two LEDs will flash rapidly.
To leave the configuration mode and return
a Model 71 to normal operation requires
one last action: again press and hold its
configuration button for two seconds. The
selected configuration parameters will be
stored in a nonvolatile memory device that
is located inside this specific Model 71.