Misc. control cvs, Description – SoundTraxx SoundCar Technical Reference User Manual
Page 66

Tsunami SoundCar Technical Reference
Page 64
CV 228
Intelligent Consisting
Function Output Location
Description
CV 228 sets the function key assignment to activate Intelligent Consisting
once the decoder has entered into “waiting mode” for a signal from the
command station to add it to the consist.
FOL 0-3: Function Output Location
1 = F1 output location
.
.
.
12 = F12 output location
0:
Not used. Must be set to 0.
Default Value: 8
Related CVs: CVs 33-46 (Function Output Map)
Misc. Control CVs
Bit 7
Bit 0
0
0
0
0
FOL3
FOL2
FOL1
FOL0