beautypg.com

Sound control cvs, Cv 113 quiet mode time-out period, Description – SoundTraxx SoundCar Technical Reference User Manual

Page 50

background image

Tsunami SoundCar Technical Reference

Page 48

CV 113
Quiet Mode Time-out Period

Description

When CV 113 is set to a non-zero value, sound effects are only activated

when the decoder is addressed. When the model is stopped and all functions

have been turned off, sound effects will turn off automatically after the quiet

mode time-out period has elapsed.

Q0-Q7:

Quiet Mode Time-out Period

0 = Sound effects turn on a few seconds after power is

turned on

1 = Minimum time-out period (0.25 seconds)

.

.

.

255 = Maximum time-out period (63.75 seconds)

Additional Information

The time-out period is calculated in seconds as:

Time-out Period (seconds) = CV 113 x 0.25

Default Value: 0

Sound Control CVs

Bit 7

Bit 0

Q7

Q6

Q5

Q4

Q3

Q2

Q1

Q0