CV 113
Quiet Mode Time-out Period
Description
When CV 113 is set to a non-zero value, sound effects are only activated
when the decoder is addressed. When the model is stopped and all functions
have been turned off, sound effects will turn off automatically after the quiet
mode time-out period has elapsed.
Q0-Q7:
Quiet Mode Time-out Period
0 = Sound effects turn on a few seconds after power is
turned on
1 = Minimum time-out period (0.25 seconds)
.
.
.
255 = Maximum time-out period (63.75 seconds)
Additional Information
The time-out period is calculated in seconds as:
Time-out Period (seconds) = CV 113 x 0.25
Default Value: 0
Sound Control CVs
Bit 7
Bit 0
Q7
Q6
Q5
Q4
Q3
Q2
Q1
Q0