Primary cvs, Cv 22 consist function group 2, Description – SoundTraxx SoundCar Technical Reference User Manual
Page 18

Tsunami SoundCar Technical Reference
Page 16
Primary CVs
CV 22
Consist Function Group 2
Description
This CV defines the Group 2 functions that may be controlled by packets sent
to the decoder’s consist address. Disabled functions may be controlled only
from the decoder’s primary or extended address.
F0(f):
Consist Function 0, Forward Enable
0 = Function disabled in consist operation
1 = Function enabled in consist operation
F0(r):
Consist Function 0, Reverse Enable
0 = Function disabled in consist operation
1 = Function enabled in consist operation
F9-F12:
Consist Functions 9-12 Enable
0 = Function disabled in consist operation
1 = Function enabled in consist operation
0:
Not used. Must be set to 0.
Additional Information
Among other things, this register allows you to differentiate headlight and
backup light functions for the lead engine and other units in the consist.
Default Value: 16
Related CVs: CV 19 (Consist Address)
CV 21 (Consist Function Group 1)
Bit 7
Bit 0
0
0
F12
F11
F10
F9
F0(r)
F0(f)