Tsunami SoundCar Technical Reference

Page 10

Primary CVs

CV 15
CV Unlock Register

Description

CV 15 contains a value from 0 to 7 that is used to unlock access to the

decoder’s CVs in a multi-decoder installation.

CV 15 may always be written or verified regardless of the decoder’s lock

status. However, an acknowledgment will only be generated when the

decoder is unlocked.

D0-D2:

CV Unlock Code

0:

Not used. Must be set to 0.

Additional Information

Locked State

If CV 15 does not match CV 16 (CV Lock ID Code), all read and write

operations to the decoder will be ignored and no acknowledgment will be

generated.

Unlocked State

Access to the decoder’s CVs will only be possible when CV 15 = CV 16.

Note: Bit 0 (CV Lock Enable) in CV 30 (Error Information/Alternate Mode

Selection) must be set to enable the lock feature in CVs 15 and 16.

Default Value: 0

Related CVs: CV 16 (CV Lock ID Code)

CV 30 (Error Information/Alternate Mode Selection)